Answers are grounded in this paper and cite their sources.
Helicopters operating in harsh desert environments are exposed to dust and sand ingestion, which can severely affect turboshaft engine performance and durability. Axial cyclone tube separators, including Vortex Tube Separators (VTS), are widely used for particle removal; however, most previous studies have focused on isolated separators rather than their practical arrangement in arrays. This study investigates the separation performance of six-unit HEAPS and VTS arrays and compares them with isolated configurations to quantify the effects of array arrangement on filtration performance. Evaluation of separation efficiencies involves varying particle sizes and inlet velocities. The results show that the array configurations generally exhibit lower separation efficiencies than the corresponding single-tube configurations, with maximum efficiencies of 77.8% for the VTS array and 94.18% for the HEAPS array, compared with 92% and 100% for the corresponding single tubes, respectively. This reduction is mainly attributed to increased turbulence and recirculation within the scavenge channel, scavenge chamber and inter-tube regions. The turbulence kinetic energy reaches approximately 60–90 m 2 /s 2 in the scavenge channel and 40–70 m 2 /s 2 between adjacent tubes. Furthermore, pressure drop increases with inlet velocity, ranging from approximately 0.12–2.0 kPa for the VTS array and 0.25–4.3 kPa for the HEAPS array.
No takes yet. Share an insight, caveat, or question.
Ghodbane et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: