Answers are grounded in this paper and cite their sources.
Walking speed can alter gait-symmetry measures and complicate interpretation of repeated biomechanical assessments. This study examined speed-dependent changes across temporal, phase-coordination, spatial, and load-related domains during treadmill walking. Ten university students aged 18–20 years completed 60 s trials at 15 imposed speeds from 0.1 to 6.0 km/h. Three synchronized cameras with MediaPipe Pose and multicamera triangulation were used to reconstruct foot trajectories, while six load sensors provided center-of-pressure and total vertical-load signals. Nine outcomes were analyzed using linear, quadratic, and restricted cubic spline models selected by AICc; significance was assessed with participant-aware permutation tests with Holm correction and uncertainty with participant-level cluster bootstrap intervals. Across 0.1–6.0 km/h, all nine outcomes showed significant associations with speed, with the largest interlimb differences and phase-coordination errors at very slow speeds. In the 1.5–6.0 km/h sensitivity range, mixed-effects models supported global speed associations for four outcomes, while a participant-level sign-flip test did not retain significance after Holm correction. Walking speed therefore influences gait symmetry nonlinearly and in a domain-specific manner. These results support reporting and controlling walking speed when comparing gait outcomes during repeated treadmill assessments.
No takes yet. Share an insight, caveat, or question.
Potlov et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: