Electromagnetic acoustic transducers (EMATs) used for in-pipe wall-thickness inspection often exhibit low transduction efficiency and limited echo sensitivity. To address this limitations, a magnetic flux concentrator (MFC) is introduced as a key structural component to enhance the bias magnetic field distribution. In this study, an EMAT design incorporating an MFC is proposed for confined in-pipe inspection. The effects of MFC geometry and material properties on magnetic field distribution and transduction performance are systematically investigated using orthogonal-design-based multiphysics simulations, followed by experimental validation. The results indicate that the MFC height and short-edge width are the dominant geometric factors, while long-edge width has a smaller influence. Under the strong bias-field conditions considered, silicon steel performs better than permalloy because of its higher saturation magnetic flux density. With the optimal configuration, the echo amplitude increase by approximately 34%, the thickness measurement error decreases to 0.12%, and the magnetic attraction force is simultaneously decreased. These results demonstrate that MFC-based magnetic circuit optimisation provides an effective and practical approach for improving EMAT performance in confined in-pipe inspection applications.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: