Answers are grounded in this paper and cite their sources.
Eight plant-physics options were added to ParFlow-CLM, spanning photosynthesis, canopy structure, and root-zone water use, including compensatory uptake plus Plant Functional Type (PFT)-aware water stress curves. I computed CW3E forcing bias at all AmeriFlux sites, then selected 13 that combine low forcing bias with broad coverage of land cover type, aridity, and geography. These span seven International Geosphere-Biosphere Programme (IGBP) land cover types across the conterminous US. A suite of physics parameterization combinations was simulated and the results were compared to site observations using metrics that spanned daily-cycle, daily-averages and annual averages. The cumulative changes reduced mean latent-heat bias from −26.7 to −6.7 W m−2 and increased mean KGE from 0.31 to 0.55. Medlyn stomatal conductance and compensatory root water uptake combine to provide improvement at specific sites, and a PFT-specific saturation-based case was the best overall configuration.
No takes yet. Share an insight, caveat, or question.
R. M. Maxwell (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: