Answers are grounded in this paper and cite their sources.
Background/Objectives: PRAM-derived total arterial impedance (Ztot) is a waveform-derived index reflecting global arterial opposition to ventricular ejection. Although available through Pressure Recording Analytical Method (PRAM)-based monitoring, the patient-level distribution of Ztot under defined intraoperative hemodynamic conditions has not been characterized. We aimed to characterize this threshold-conditioned distribution in adults undergoing elective coronary artery bypass grafting (CABG) and assess its associations with key hemodynamic variables. Methods: In this single-center retrospective observational study, high-resolution intraoperative data from PRAM-based MostCare® monitoring were analyzed. Of 437 screened patients, 109 met predefined signal-quality and hemodynamic criteria. Variables were recorded at 30-s intervals, and patient-level medians were used to address repeated measurements. Among recordings meeting the predefined hemodynamic criteria, the threshold-conditioned distribution of Ztot was summarized using the 2.5th and 97.5th percentiles of patient-level median values. Results: The median patient-level Ztot was 0.451 mmHg·s/mL. The primary cohort’s threshold-conditioned 2.5th and 97.5th percentile limits were 0.315 and 0.615 mmHg·s/mL, respectively (90% bootstrap confidence intervals: 0.302–0.370 and 0.542–0.638). In a sensitivity analysis restricted to 72 patients with at least six eligible measurements, the 2.5th percentile limit was similar (0.316 mmHg·s/mL), whereas the 97.5th percentile limit was lower (0.505 mmHg·s/mL). Ztot was negatively correlated with cardiac cycle efficiency (CCE) (ρ = −0.556, p < 0.001) and positively correlated with effective arterial elastance (Ea) (ρ = 0.547, p < 0.001) and systemic vascular resistance (SVR) (ρ = 0.472, p < 0.001). No significant association with stroke volume variation was observed (ρ = −0.004, p = 0.963). Ztot showed a weak inverse association with PPV that did not reach statistical significance in the primary cohort (ρ = −0.180, 95% CI: −0.357 to 0.010, p = 0.062). Conclusions: In this selected elective CABG cohort, PRAM-derived Ztot was characterized by a threshold-conditioned patient-level distribution under the predefined intraoperative hemodynamic criteria. These estimated percentile limits should not be interpreted as a population-wide physiological normal range. Exploratory associations between Ztot and selected hemodynamic variables were observed; independent prospective studies are needed to assess their reproducibility and clinical relevance.
No takes yet. Share an insight, caveat, or question.
Yılmaz et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: