Key result
Penumbra mechanical thrombectomy achieves complete recanalization of internal carotid artery occlusion following TAVI.
Why the study?
Periprocedural stroke remains one of the most serious complications of TAVI in patients with severe aortic stenosis at high surgical risk, significantly affecting prognosis and quality of life.
Case Report (n=1)
Prompt diagnosis and immediate mechanical thrombectomy can achieve complete recanalization and improve outcomes in patients experiencing acute ischemic stroke as a complication of TAVI.
Answers are grounded in this paper and cite their sources.
Supports feasibility of thrombectomy for post-TAVI stroke; hypothesis-generating and leaves open efficacy in larger cohorts.
Introduction. Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis in patients at high surgical risk. Despite its favorable safety profile, periprocedural stroke remains one of the most serious complications, significantly affecting patients’ prognosis and quality of life. Case presentation. A 71-year-old man with severe aortic stenosis, chronic obstructive pulmonary disease (COPD), permanent atrial fibrillation, and a previously implanted permanent pacemaker due to second-degree atrioventricular block was selected for TAVI because of high surgical risk. Following transfemoral implantation of a 34-mm Evolut R valve, the patient developed symptoms of acute ischemic stroke, including speech impairment and left-sided hemiparesis. Computed tomography (CT) showed no significant intracranial hemorrhage, while digital subtraction angiography (DSA) demonstrated occlusion of the right internal carotid artery. Mechanical thrombectomy was performed using the Penumbra system, resulting in complete recanalization. Follow-up imaging revealed ischemic brain lesions without evidence of hemorrhagic transformation, and echocardiographic assessment performed one week later confirmed normal function of the implanted prosthetic valve. Discussion. Stroke is one of the most severe complications associated with TAVI. The main risk factors include advanced age, vascular disease, and atrial fibrillation. Prompt diagnosis and immediate access to endovascular treatment are crucial for improving clinical outcomes. Conclusions. Transcatheter aortic valve implantation is an effective treatment option for patients with severe aortic stenosis who are at high surgical risk; however, careful monitoring for neurological complications is essential. Early neuroradiological intervention, including mechanical thrombectomy, may significantly improve patient outcomes and prognosis.
No takes yet. Share an insight, caveat, or question.
Kozak et al. (2026) conducted a case report in Acute ischemic stroke complicating transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (n=1). Mechanical thrombectomy using the Penumbra system following transfemoral TAVI (34-mm Evolut R valve) was evaluated on Recanalization of the occluded right internal carotid artery and prosthetic valve function. Mechanical thrombectomy using the Penumbra system achieved complete recanalization of right internal carotid artery occlusion after 34-mm Evolut R TAVI in a 71-year-old man.
Synapse has enriched 10 related papers. Consider them for comparative context: