POCUS detects acute aortic syndrome in the emergency department with ~88% sensitivity.
Why the study?
Acute aortic syndromes are easily misdiagnosed in the emergency department, and despite guideline recommendations for focused transthoracic echocardiography as a first-line tool, the reported diagnostic performance of point-of-care ultrasound varies considerably across existing literature.
Does point-of-care ultrasound accurately detect acute aortic syndrome in adult patients presenting to the emergency department with suspected aortic pathology?
Meta-Analysis (n=4,855)
Yes
Does point-of-care ultrasound accurately detect acute aortic syndrome in adult patients presenting to the emergency department with suspected aortic pathology?
Point-of-care ultrasound demonstrates high specificity (98.6% for direct signs) for ruling in acute aortic syndrome in the emergency department, though its moderate sensitivity means negative sonographic findings alone cannot reliably rule out the diagnosis.
Answers are grounded in this paper and cite their sources.
High specificity supports POCUS as a rule-in test for acute aortic syndrome; extends guideline recommendations but leaves open optimal workflow integration.
BACKGROUND: Acute aortic syndromes (AAS) are a group of aortic disorders with a wide range of presentations that are easily misdiagnosed in the emergency department (ED).The European Society of Cardiology Guidelines 2024 recommended focused transthoracic echocardiography as the first-line imaging tool for the detection of aortic dissection, but the performance of point-of-care ultrasound (POCUS) in detecting AAS in ED varies considerably in the existing literature.We aim to gather and synthesize existing studies to provide a more comprehensive overview of the diagnostic accuracy and value of POCUS for the detection of AAS and its generalizability in the ED setting.METHODS: Ovid MEDLINE, EMBASE, Web of Science, and the Cochrane Library were searched for studies published from
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) conducted a meta-analysis in Acute aortic syndrome (n=4,855). Point-of-care ultrasound (POCUS) vs. Reference standard (CTA, advanced imaging, or 30-day clinical follow-up) was evaluated on Diagnostic accuracy (sensitivity, specificity, and SROC AUC) of any sonographic signs on POCUS for detecting acute aortic syndrome (Sensitivity 88.3%, Specificity 80.3%, SROC AUC 0.91, 95% CI 85.1%-91.2%). Point-of-care ultrasound detected acute aortic syndrome in the emergency department with 88.3% sensitivity, 80.3% specificity, and 98.6% specificity for direct sonographic signs.