Vaccine cold-chain failures remain a major and preventable cause of vaccine wastage worldwide, and the problem is especially acute in rural, resource-constrained health facilities where unreliable electricity, limited technical support, and unreliable internet connectivity compound the risk. This work presents the design, testing, and prototype implementation of an edge-AI-informed monitoring system for vaccine refrigeration units, motivated by the documented cold-chain challenges faced by rural health clinics in Ghana. Existing systems are largely reactive, alerting only after a temperature threshold has been breached, and many depend on the cloud. The proposed system combines three detection layers that run locally on a low-cost ESP32-S3 microcontroller: (1) predictive compressor-fault detection based on a machine-learning analysis of cycling behaviour, (2) gas-based detection of likely non-vaccine items placed in the unit, and (3) cumulative exposure tracking using a real-time clock. The predictive approach was first tried on the public MetroPT-3 dataset of a failing metro-train air compressor. With a time-ordered train and test split, it flagged 81 of 83 documented failure hours and 4.7% of later normal hours (ROC AUC 0.98), although the result depends on how a compressor cycle is defined. It was then applied to a purpose-built simulation of vaccine-fridge degradation. The analysis was turned into lightweight threshold rules that run on the microcontroller and were tested in a simulated hardware environment (Wokwi), including an MQTT reporting layer and a web dashboard. Decision-logic timing and the effect of network conditions on loop timing were also measured on a real ESP32-S3 using synthetic inputs. The rule was also replayed on recorded power traces of household fridges and freezers from three UK homes (REFIT dataset). With the initial settings it raised false Warnings between about 5 and 28 times per 30 days on healthy appliances. A longer calibration with a persistence requirement, chosen by leave-one-house-out testing, reduced false Warnings by about a third to 70% and false Criticals by about two-thirds or more, at the cost of slower detection of injected faults, and false alarms did not disappear. These settings are now the firmware default, and a replay of the recorded phases on an ESP32-S3 gave the same alert sequences as the analysis. An Isolation Forest on window features did not do better than the ratio rule on the same traces. The complete firmware was also run on the board with temperature, door and gas values generated by the sketch, and it went through calibration, Warning, Critical, recovery, the gas alert and the exposure alert without a reset. The rule was finally run on the labelled records of ten real ultra-low-temperature laboratory freezers (about 89 freezer-years, 22 service-dated faults). It raised about 0.15 Warning episodes per 30 days in healthy time, but it flagged only 4 of 14 compressor or refrigerant faults in the 90 days before their service dates, and in 12 of 18 long unlabeled episodes the freezer's own warm alarm, shutdown or failure to reach its setpoint followed within 10 days. The complete system has not yet been tested with physical sensors or on a physical refrigerator. This document describes the related work, the methods, the system design, the results, and the limitations and next steps.
No takes yet. Share an insight, caveat, or question.
Adu-Gyamfi Kwadwo (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: