Answers are grounded in this paper and cite their sources.
. After ThT binds to these structures, a clear fluorescence output is generated. Benefiting from the effectively suppressed background leakage by the hairpin design and the significantly enhanced signal generation enabled by the EXPAR-RCA cascade, the assay exhibits excellent analytical performance. The fluorescence response shows a good linear correlation over the range of 10 fM to 10 nM, with a limit of detection (LOD) of 1.58 fM. The method also demonstrates high selectivity toward miRNA-21, capable of discriminating single-base mismatched sequences. Furthermore, analysis of diluted serum and cellular RNA samples demonstrated the preliminary applicability of the proposed strategy in biological matrices. The method provides a convenient, low-cost, and highly sensitive analytical platform for miRNA detection and bioanalytical research.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: