Answers are grounded in this paper and cite their sources.
OVCFs commonly cause pain and functional impairment. PKP is widely used, but conventional fluoroscopy-guided puncture may require repeated adjustments, increasing radiation exposure and procedural burden. Patient-specific 3D-printed body-surface guides may facilitate individualized puncture planning. We evaluated procedural, radiographic, and short-term clinical outcomes of guide-assisted PKP compared with conventional PKP. This single-center retrospective comparative cohort included consecutive adults with single-level osteoporotic vertebral compression fractures treated from August 2023 through August 2024. Patients were classified according to the technique received: guide-assisted PKP ( n = 72) or conventional PKP ( n = 83). Procedural outcomes, including operative time, fluoroscopic exposure count, device-recorded Total DAP, and injected cement volume, were analyzed in all 155 patients. CT-detected cement leakage was evaluated in 129 patients, and longitudinal clinical and radiographic outcomes, including VAS, ODI, anterior vertebral height, and Cobb angle, were analyzed in 145 patients with complete postoperative follow-up. Longitudinal outcomes were analyzed using mixed-effects models, and overlap weighting was used as a sensitivity analysis for procedural outcomes. Among 155 eligible patients, guide-assisted PKP was associated with shorter operative time (mean difference, − 5.88 min; 95% CI, − 7.91 to − 3.86), fewer fluoroscopic exposures (− 3.57; 95% CI, − 4.22 to − 2.93), lower Total DAP (geometric mean ratio, 0.755; 95% CI, 0.712 to 0.801), and lower recorded injected cement volume (− 0.94 mL; 95% CI, − 1.29 to − 0.59); all four FDR-adjusted P values were < 0.001. CT-detected leakage occurred in 2/62 (3.2%) and 10/67 (14.9%) patients (risk difference, − 11.7% points; 95% CI, − 22.4 to − 1.5; Fisher P = 0.032). No significant postoperative between-group differences were observed for VAS or ODI. The 1-week anterior height difference was not significant after Holm adjustment ( P = 0.102), whereas a small Cobb-angle difference remained at 1 week ( P = 0.011); neither radiographic difference persisted at 1 month. Interobserver reliability of radiographic measurements showed single-measurement ICCs ranging from 0.821 to 0.882. In this cohort, guide-assisted PKP was associated with shorter operative time, fewer fluoroscopic exposures, and lower intraoperative Total DAP. A lower recorded injected cement volume was observed in the overall cohort, and a lower frequency of CT-detected leakage was observed in the CT-evaluated subgroup. No significant between-group differences in short-term pain or disability outcomes were observed, and radiographic differences were not sustained at 1 month. Prospective studies with quantitative accuracy assessment are needed to further evaluate this guide-assisted workflow. Not applicable.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: