Answers are grounded in this paper and cite their sources.
High-volume recycled concrete powder (RCP) can reduce cement consumption but often causes pronounced losses in strength and dimensional stability associated with shrinkage. This study examined bamboo fiber (BF) reinforcement in high-RCP mortar by varying fiber length, dosage, and surface condition, and by combining mechanical tests, 0–28 d shrinkage monitoring, direct pull-out tests, and multiscale characterization. A 45% RCP replacement level was selected as the representative high-replacement matrix. Within the investigated range, 18 mm BF at 1.0% of total binder mass provided the best overall mechanical response. Sequential NaOH–KH550 treatment further improved fiber–matrix bonding, increasing the equivalent interfacial bond strength from 9.68 to 15.55 MPa (+60.6%). RCP mainly governed hydration development and pore structure, whereas BF acted through crack bridging, interfacial stress transfer, and deformation restraint. Incorporating 1.0% BF reduced the 28 d shrinkage magnitude of R0, R15, R30, R45, and R60 mortars by 25.0%, 28.3%, 38.0%, 55.4%, and 12.6%, respectively. The maximum inhibition at R45, followed by a sharp decline at R60, suggests that fiber efficiency depends on matrix condition rather than RCP content alone. The results identify a reinforcement window in which suitable BF geometry, dosage, and surface modification can partly compensate for deterioration associated with high RCP replacement.
No takes yet. Share an insight, caveat, or question.
Wei et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: