Answers are grounded in this paper and cite their sources.
Background/Objectives: long axial field-of-view (LAFOV) PET systems have recently emerged as a promising tool for improving quantitative imaging after [90Y] radionuclide therapy. This narrative review summarizes the current literature evidence on this field of research. Methods: a literature review was performed to identify studies evaluating the clinical application of LAFOV PET for [90Y] dosimetry, focusing on quantitative accuracy, protocol optimization, and comparison with conventional imaging systems. The search was performed on PubMed/MEDLINE, Scopus, and Embase; it was updated until 15 June 2026. A total of 37 papers were extracted and finally 5 papers were selected to be included in the review. Results: even if limited, available evidence seems to indicate that LAFOV PET provides improved quantitative accuracy, lower image noise, and superior dose recovery compared with conventional SAFOV PET, particularly for small lesions. Optimized reconstruction protocols allow acquisition times to be reduced to 20 or even 5 min without significantly affecting dosimetric accuracy, whereas 1-min acquisitions remain suboptimal because of increased image noise. LAFOV PET also enables reliable tumor, liver, and lung dosimetry, with measured tumor absorbed doses generally showing good agreement with pre-treatment predictions. Compared with post-treatment SPECT, LAFOV PET provides comparable organ dosimetry while offering improved quantitative performance. Conclusions: current evidence seems to support the use of LAFOV PET as a valuable technique for accurate post-treatment [90Y] dosimetry. Further multicenter clinical validation is warranted to facilitate its routine implementation in clinical practice.
No takes yet. Share an insight, caveat, or question.
Dondi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: