Answers are grounded in this paper and cite their sources.
Pit Thermal Energy Storage (PTES) is one of the most cost-effective seasonal storage technologies available to support Australia's transition to a net-zero energy system. Its floating geosynthetic insulation cover is the most thermally critical and expensive PTES component, accounting for 40–60% of system cost and driving most operational heat loss. This study presents a novel coupled heat- and mass-transfer framework for a PTES geosynthetic-insulation cover system tailored to Australian conditions. The model accounts for radiative exchange, atmospheric emissivity, ambient temperature dynamics, and wind-driven convection, with moisture transport described by Stefan diffusion and driven by saturation vapour pressure gradients. Comparative simulations between a heat-transfer reference model and a coupled heat-and- mass-transfer model representing a non-functional drainage system were conducted to quantify heat losses from a cover- system PTES facility located in Northern Victoria. The results show that coupled heat and moisture transport governs cover performance. The surface heat-transfer coefficient increased fivefold (from 0.15 to 0.80 W/m²·K), and cumulative weekly heat loss increased sixfold (from 6.3 to 37.5 MJ/m²). These findings are consistent with moisture-induced insulation deterioration documented at European PTES facilities. The validated framework provides a rigorous basis for optimising cover thickness, material specification, and drainage design across Australian climate zones.
No takes yet. Share an insight, caveat, or question.
Kabir et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: