Answers are grounded in this paper and cite their sources.
Façades with large glazed areas are common in commercial buildings in Dhaka, where a hot-humid climate makes cooling a major energy end use. Semi-transparent photovoltaic (STPV) glazing can generate electricity while admitting daylight, but it also reduces daylight availability and changes solar heat gain, so its net benefit is not obvious, and studies for Bangladesh that combine glazing transmittance, glazed fraction, façade orientation and cost are limited. This study uses EnergyPlus 24.2 with a Dhaka typical-year weather file to evaluate five glazing systems (clear double glazing, solar-control Low-E double glazing, and STPV double glazing with visible light transmittance (VLT) of 40%, 30% and 20%) on a 20 m × 15 m single-floor office with window-to-wall ratios (WWR) of 20%, 40% and 60% on north-, east-, south- and west-facing façades, giving 60 annual simulations. The performance metric is net annual electricity use: cooling, lighting with daylight dimming and equipment, minus STPV generation. STPV gave the lowest net electricity in 6 of the 12 WWR– orientation combinations, all at WWR of 40% or more. The best case was a south-facing façade with 60% WWR and VLT 20%, at 63.3 kWh/m²·yr, which is 17.1% below clear glazing and 9.3% below Low-E glazing. At 20% WWR, STPV increased net electricity by 2.3–6.3% relative to Low-E glazing because the lighting penalty outweighed the small generation area. The glazing properties, STPV efficiencies and costs are assumed representative values. A sensitivity analysis over STPV output (×0.25 to ×2.5) shows that the energy conclusions depend strongly on STPV efficiency. The model was verified (geometry, generator calculation, and an independent solar-radiation calculation agreeing within 0.31%) and benchmarked against published office energy-use figures, but it was not validated because no measured data were available. An economic analysis with assumed installed costs and the June 2026 BERC tariffs found no case in which STPV had a positive net present value or a payback within 25 years at mid-range cost against Low-E glazing. A Monte Carlo analysis of the economic inputs gave a positive net present value in 0.02% of 20,000 draws for the best case; for the best case to break even, STPV would need an installed cost of about 1.7 to 2.6 times that of Low-E glazing.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: