Answers are grounded in this paper and cite their sources.
We show for the first time that the sampled characteristic of a Langmuir probe obeys an exact discrete recurrence, and derive what the sweep circuit adds. Below the knee every probe forms a pair with its return electrode, whose electron share y obeys the Beverton–Holt map yn+1 = λyn/[1 + (λ − 1)yn] exactly at any step, with the Boltzmann factor λ = ee∆V /kTe as multiplier. Its consequences are reported here for the first time. (i) The floating double probe cannot period-double at any step; period doubling read into probe traces is a forward-Euler artefact. (ii) The single probe is the same map truncated at yknee = R/(1+α), where R is the electron-to-ion saturation ratio and α the return-to-probe area ratio. The knee is a singularity of order 1 + k/2, and this truncation, not logistic dynamics, produces the Verhulst-like look. (iii) A floating pair stepped through lead capacitance records a two-variable map whose hidden common-mode state, slowing as density falls, produces sweep-direction hysteresis and fixes the admissible step and dwell. Published measurements confirm the recurrence. A xenon double-probe trace, reduced at each tip’s own sheath potential, recovers the geometric area ratio, showing that the offset recently judged unresolvable is a log-odds translation. It obeys the exact map to within 1% for 1–8 V steps, where forward-Euler and Ricker maps miss by up to 21% and 16%. Segmented-anode data in argon and helium confirm the truncation with an effective saturation ratio.
No takes yet. Share an insight, caveat, or question.
Ahmed Hala (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: