Answers are grounded in this paper and cite their sources.
Regenerative braking control needs a loss model of the drive as a function of speed and deceleration. However, for a commercial in-wheel drive, often only battery-side (direct current, DC) data exist. This paper analyses the identifiability of such a model and builds an identification procedure on it. DC-side data determine the electrical parameters only up to a common scale factor when the modulation limit of the controller is unknown. For a 5 kW hub motor, the torque constant measured from the open-circuit voltage fixes this scale. Five tests check the manufacturer’s load test report against the model, and three low-speed bench events give the constant loss as 70 ± 20 W. The identified set comprises a constant drag torque of 2.71 ± 0.40 N·m and an equivalent iron loss resistance of 11.4 Ω per phase. With every constant taken at its bound, the predicted loss varies by ±16 to ±32 W, a combined bound band and not a coverage interval. On the road, the cut-off speed, below which braking returns no energy, falls to 4.1 km/h at 1.0 m/s2, so energy is recovered almost to standstill. Bench cut-off speeds are consistent with the model but not independent of the identification.
No takes yet. Share an insight, caveat, or question.
Long et al. (2026) studied this question.