Answers are grounded in this paper and cite their sources.
A review of work on recognising silent speech from surface electromyography, written from an applied standpoint: what has been achieved, on what hardware, and which problem remains unsolved. The field converges on one point: within a single recording session accuracy is high — from 68% on eight commands to 97% on seven channels — while after the electrodes are removed and reapplied it falls to 54–76%. This loss reproduces across independent groups, different hardware and different recording sites, which makes it a property of the task rather than of any one implementation. Three families of remedies are reviewed: calibration at the start of use, per-session normalisation, and geometric transfer of covariance features. The patent landscape of the field is described separately, without legal conclusions, as a map of occupied directions. Four open problems are set out, of which the principal one is not accuracy but reproducibility across sessions. Russian and English versions attached.
No takes yet. Share an insight, caveat, or question.
Fedotova Ann (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: