Answers are grounded in this paper and cite their sources.
Eye banks commonly judge a donor cornea from a single endothelial cell density (ECD) measurement and a binary accept-or-reject decision, although donor age is often treated as a proxy for endothelial quality. We analysed 485 donor corneas recovered at the Henan Eye Bank, China, between January 2019 and March 2026, all with complete ex vivo specular microscopy records. ECD, the coefficient of variation of cell area (CV) and hexagonality (HEX) were described, and their associations with donor age, sex, cause of death and cold ischaemia time were examined with non-parametric tests and multivariable linear regression. Median ECD was 2489 cells/mm² (interquartile range 2022–2895; range 812–4310); mean CV was 51.67% and mean HEX 45.14%, so polymegathism and pleomorphism were common. ECD did not differ by sex, and no cause-of-death category remained significant after adjustment for multiple comparisons. Donor age was the only variable associated with ECD, but the effect was small (− 5.01 cells/mm² per year) and the model explained 2.5% of the variance. We propose a four-tier framework (excellent > 2800, qualified 2000–2800, marginal 1500–2000, unacceptable ≤ 1500 cells/mm²) that makes donor assessment explicit and comparable between banks. The thresholds are preliminary and require validation against transplant outcomes.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: