The experimental fusion reactor ITER relies on neutral beam injectors as auxiliary heating system, providing 33 MW of heating power to the fusion plasma. ITER neutral beams are obtained through neutralisation of negative ion hydrogen/deuterium beams accelerated up to 1 MeV. The ion source consists of an inductively coupled plasma powered by radio-frequency (RF) generators, where a magnetic filter field is necessary to lower electron temperature and density in the extraction region, minimizing the destruction of negative ions. However, an excessive filter field in the driver region was found to limit the RF coupling, motivating the investigation of a magnetostatic shield placed around the RF drivers to screen stray magnetic fields and reduce the filter field effect on the driver plasma, without compromising electron filtering in the extraction region.This work presents a plasma characterization study of the magnetostatic shield effect, tested at SPIDER and MINION, two test facilities hosted at Consorzio RFX in Padova (Italy) within the Neutral Beam Test Facility (NBTF). Results from SPIDER are discussed, focusing on plasma properties measured with Langmuir probes and optical emission spectroscopy, supported by a Collisional Radiative (CR) model. It is shown that the extracted negative ion current density is nearly unaffected by the shield, even at high filter field values, while a wider range of plasma grid currents becomes accessible without left-right asymmetry in the RF driver pairs.