Conventional field-oriented control (FOC) of induction motor drives typically employs a fixed flux reference, leading to reduced energy efficiency, particularly under light-load conditions due to excessive excitation and increased losses. To address this limitation, this paper proposes a lightweight Hessian-free adaptive flux optimization strategy. A simple real-time update law for the d-axis current is developed, enabling effective loss minimization without requiring second-order derivative computation, iterative optimization, or additional hardware. By capturing the nonlinear coupling between torque demand and excitation, the method dynamically adjusts the flux while preserving the conventional FOC structure. Experimental results demonstrate significant efficiency improvement over a wide operating range, with efficiency increasing from 31.02% to 61.87% under light-load conditions and from 69.07% to 77.61% at rated load compared to conventional PI-based FOC. The proposed approach provides a low-complexity solution suitable for real-time industrial applications.
No takes yet. Share an insight, caveat, or question.
Ngoc Thuy Pham (2026) studied this question.