Tangential ultrasonic welding without energy directors places carbon fiber-reinforced polyether ether ketone (CF/PEEK) laminates in direct contact. The spatial distribution of interfacial bonding provides a basis for understanding joint load-bearing performance. This study combines an interfacial frictional heating model, lap shear testing, industrial computed tomography (CT) of representative joints, and fracture-surface observations. Thermal responses and bonding characteristics are compared across welding force, amplitude, and time series. The calculations locate high-temperature regions mainly at the overlap edges and predict higher edge temperature peaks with increasing amplitude. At 150 N and a single-sided amplitude of 12 µm, the 800 ms joint reached the highest measured apparent lap shear strength, 9.84 MPa. Its effective fracture-surface area fraction was 46.0%. The corresponding values for the 1000 ms joint were 5.73 MPa and 32.9%, accompanied by local gaps and resin extrusion. Effective fracture-surface area fractions and strengths changed in the same direction in the amplitude and time series. The force series exhibited a different area–strength relationship. CT and microscopic fracture-surface observations linked these differences to interfacial continuity, local pores, and material damage. The results support assessing joints without energy directors through both effective fracture-surface coverage and local bonding conditions.