Spillways are hydraulic structures designed to regulate the storage levels of dams. Their discharge capacity is dependent on the geometric characteristics of the crest and influences interactions with downstream elements. Flow analysis in these structures can be performed using numerical methods, such as CFD. This study presents a hydraulic and hydrodynamic comparison of two distinct geometric configurations for a spillway crest applying a reduced-width approach. A 3D digital model of the spillway geometry was created to simulate different discharge scenarios. Numerical simulations were conducted using ANSYS-FLUENT software, employing the Reynolds-Averaged Navier–Stokes (RANS) framework and the k-ε turbulence model. Results indicated that hydrodynamic flow behaviour and cavitation phenomena were relatively similar for both crest geometries. Globally, the discharge coefficient C was estimated at 1.78 for the broad-crest and 2.13 for the Ogee crest. On the other hand, the lowest cavitation index values were 2.11 and 2.14, respectively, for a discharge of 5,213.5 m3/s. Stress distribution exhibits significant variation on the initial chute sidewalls for the minimum scenario, where the stress ratio shows an oscillation of 15.8 times the pressure for the Ogee crest compared to the broad crest in the internal region of the step. The intermediate and maximum scenarios showed minor differences in stress ratio.
No takes yet. Share an insight, caveat, or question.
Guerra-Cobián et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: