This manuscript presents the design and experimental validation of an LLC resonant converter for electric vehicle (EV) battery charging. The proposed topology integrates the transformer magnetising inductance with a resonant tank formed by an inductor and a capacitor, enabling zero-voltage switching (ZVS) of all main switches throughout the entire charging process and zero-current switching (ZCS) to boost the current under charging conditions. The charger delivers a wide output-voltage range suitable for battery systems, while the transformer transfers energy under low-output-voltage conditions. High efficiency and a narrow frequency variation range are achieved under load conditions. The LLC resonant topology inherently reduces switching losses and improves efficiency. Compared with a conventional LLC converter, the proposed charger exhibits superior performance in the constant-voltage stage. An experimental prototype was built and tested at an input voltage of 220 V, producing an output voltage of 36–58 V and an output power of 495 W, with a measured efficiency of 94%.
No takes yet. Share an insight, caveat, or question.
Ahsan et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: