Answers are grounded in this paper and cite their sources.
This study investigates the collapse resistance of a three-story steel frame substructure (SFS) equipped with sliding inner cores (SIC), aiming to elucidate the mechanisms by which joint-strengthening strategies enhance structural performance. The test results reveal a multistage failure process, evolving from slab cracking and beam flange buckling/fracture to overall damage induced by SIC engagement. Quantitative resistance analysis shows that flexural, Vierendeel, and catenary mechanisms contribute 66.2%, 19.3%, and 14.5% to the overall resistance, respectively, identifying flexure as the dominant contributor, followed by secondary Vierendeel and catenary actions. While flexural contributions remain relatively uniform across floors, the catenary contribution declines markedly from the bottom to the top. Using a validated numerical model, the enhancement mechanism of the SIC was investigated. Results indicate that SICs improve joint flexural stiffness at each floor and establish a secondary load path that significantly amplifies tensile forces in the composite beams of the first and second floors, with minimal impact on the third. Quantitatively, SICs enhance structural resistance in the elastic-plastic, plastic, transitional, and catenary stages by 14.3%, 34.1%, 70.2%, and 71.6%, respectively.
No takes yet. Share an insight, caveat, or question.
Meng et al. (2026) studied this question.