Answers are grounded in this paper and cite their sources.
The relationship between donor graft thickness and visual recovery after Descemet stripping automated endothelial keratoplasty (DSAEK) is well recognized, but whether differences in thickness within the ultrathin range affect visual outcomes remains unclear. We retrospectively reviewed 87 ultrathin DSAEK procedures in 79 eyes (graft thickness, 42–100 μm) with at least 6 months of follow-up. Six-month best spectacle-corrected visual acuity (BSCVA), expressed as the logarithm of the minimum angle of resolution (logMAR), was analyzed as a continuous outcome using univariable and multivariable linear regression. An exploratory receiver operating characteristic (ROC) analysis was also performed. Mean logMAR BSCVA improved from 1.44 preoperatively to 0.36 at 6 months. Worse preoperative BSCVA (B = 0.127, p = 0.018) and thicker donor grafts (0.07 logMAR per 10 μm; 95% confidence interval [CI], 0.03–0.10; p < 0.001) were independently associated with worse 6-month visual acuity. Eyes with worse preoperative BSCVA showed greater visual improvement (p < 0.001). Previous glaucoma surgery was not independently associated with visual outcome among eyes whose grafts remained clear for 6 months. The ROC-derived graft-thickness threshold was 68.5 μm (area under the curve [AUC], 0.640). Within the ultrathin range, thinner grafts and better preoperative vision were associated with better 6-month visual outcomes.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2026) studied this question.