This is the authors' abstract. We don't add key points for this paper.
Vibration during concrete placement activities may affect the accuracy of heart rate monitoring using photoplethysmography type wrist-worn devices, as they are sensitive to motion artifacts. The objective of this study is to evaluate the effectiveness of health monitoring during concrete placement using a commercial wrist-worn device by comparing it against a chest strap-based electrocardiogram device. Data were collected from two full-scale concrete casting experiments. Comparative analysis was carried out using three metrics: mean absolute percentage error, mean absolute error, and percentage of wrist-worn values within 10% of their corresponding chest strap-based values. Extended vibrator operation was found to erode the accuracy of the results obtained by the wrist-worn device, and the wrist-worn device was found to be unreliable during high-effort periods of vibrator operation. However, further work is necessary to confirm whether these results are consistent across a broader range of participants and concrete placement environments.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Henry et al. (2026) studied this question.