This study presents an advanced fault diagnosis framework for three-phase voltage source inverters (VSIs) by introducing two novel health indicators and leveraging machine learning techniques. The proposed indicators—ratio of Park’s current to average value and ratio of root mean square to peak-to-peak value—address the limitations of conventional features under varying load conditions. Utilizing decision trees and ensemble trees (ETs), the framework evaluates 24 fault scenarios, achieving high accuracy across 1% to 100% load range. Simulation results demonstrate that ETs with the proposed indicators attain 99.2% accuracy, surpassing traditional methods (98%) and baseline indicators (86.4%). Under light load (1% to 10%) conditions, the proposed method maintains robust performance at 95.2%, compared to 47.2% for basic features. Experimental validation confirms rapid fault detection within one cycle. These findings highlight the proposed indicators’ load-independent robustness and the efficacy of machine learning in enhancing VSI reliability.