Answers are grounded in this paper and cite their sources.
Hypoxic-ischemic brain injury (HIBI) drives mortality after cardiac arrest, yet guidelines recommend a uniform mean arterial pressure (MAP) of ≥65 mmHg despite inter-patient autoregulatory variability. This threshold derives from population-level observational data, and randomized trials have tested fixed targets. The lower limit of autoregulation may be right-shifted in some patients, so a uniform target may underperfuse the brain. This review synthesized the feasibility of personalized, autoregulation-derived blood pressure targets and their association with survival and neurological outcomes, including comparisons with fixed targets as prognostic exposures where available. This PRISMA 2020-compliant systematic review searched PubMed, Cochrane Library, ScienceDirect, and Google Scholar (first 200 results) through September 13, 2026 (English-language adult studies only). Two reviewers independently screened studies using Rayyan and extracted data, resolving disagreements by discussion or a third reviewer. Risk of bias was assessed with Quality in Prognosis Studies (QUIPS) for prognostic studies and Risk of Bias in Non-randomized Studies of Interventions (ROBINS-I) for the single interventional study; certainty of evidence was rated with Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) guidance for prognostic factors (starting at high certainty and downgraded). Feasibility was described without a GRADE rating, and the effect of active targeting was not graded because no comparative evidence exists. Findings were synthesized narratively following Synthesis Without Meta-Analysis (SWiM) guidance, grouped by research question and outcome domain (defined post hoc). Eleven adult studies (428 patients) used near-infrared spectroscopy (NIRS)-, transcranial Doppler (TCD)-, or intracranial pressure (ICP)-based indices. One study reported an individualized and four fixed MAP thresholds (65-80 mmHg) as prognostic exposures (an observational comparison of exposure metrics, not treatment strategies). Time below the individualized optimal MAP (MAPopt) was associated with lower odds of survival with a good neurological outcome at 180 days (unadjusted OR of 0.97 per percentage point, 95% CI [0.96, 0.99]; n = 33), whereas time below fixed thresholds (n = 51) was not significantly associated with this outcome. Because the samples differed, the analyses were unadjusted, and no test of the difference was performed, this does not show that the individualized metric discriminates better than fixed thresholds. MAPopt or autoregulatory lower limits exceeded 65 mmHg in all adult studies reporting them (76-114 mmHg). Impaired autoregulation or greater exposure below the individualized target was associated with mortality or unfavorable outcomes in several cohorts (adjusted HR of 4.02 for time without autoregulation; unadjusted OR of 3.6 per SD for burden below MAPopt), but not all. Feasibility was ≥83% in most NIRS- and ICP-based cohorts but 19.8-65% in four studies (denominators differed). Risk of bias was predominantly high, and certainty of evidence for prognostic associations was very low. Personalized targets have a physiological rationale, but the evidence is observational, heterogeneous, and inconsistent, and whether targeting improves outcomes remains untested. These associations are prognostic and do not show that personalized blood pressure management improves outcomes. Randomized trials are needed before clinical adoption.
No takes yet. Share an insight, caveat, or question.
Clavijo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: