Answers are grounded in this paper and cite their sources.
Two preregistered experiments (doi:10.5281/zenodo.24407897, doi:10.5281/zenodo.24419327) on ibm_marrakesh, ibm_fez and ibm_kingston; 27 jobs, 193 s QPU. RO-06, 8 rounds of an all-qubit readout probe: readout faults hidden from IBM's calibration (probe > 15%, IBM < 3%) were rare (H1 not supported); every such qubit recovered in another round (H2 supported); faults persist across 15-minute rounds 87% of the time. RO-07: readout error did not depend on context (isolated vs all-qubit readout; other qubits in 0 vs 1): all effects below 1.7 pp; both context hypotheses failed; controls clean. Exploratory: IBM's readout values did not change during 1.75 h of sampling, ibm_kingston's not for >15 h; when ibm_fez updated, the new values matched our latest probes (rho 0.95 vs 0.81 for the old values). The gap between IBM's numbers and in-job readout is stale calibration plus hour-scale qubit changes. Record contains paper, source, all counts, calibrations, locks, QPYs, analyses and code.
No takes yet. Share an insight, caveat, or question.
Devin Phillip Davis (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: