Accurate temperature prediction and cooling optimization are vital for integrated electric drive systems (EDS). This study develops a lumped parameter thermal network (LPTN) model to evaluate the global thermal behavior of a three-in-one EDS, comprising the motor, water-cooled controller, and oil-cooled reducer. Steady-state validation reveals severe thermal concentration at the motor winding ends, with winding end2 identified as the highest thermal load for detailed analysis. Simulations show winding end2 reaches 120.398°C at rated conditions (2.032% relative error vs measurements) and 117°C at peak speed (0.863% error). To address non-linear thermal dynamics during the NEDC driving cycle, a reinforcement learning (RL) algorithm was implemented to dynamically optimize cooling pump speeds. To further interpret the cooling-control behavior, equivalent pump-speed, pump-power, and cumulative pump-energy indices were reconstructed from the simulated thermal response and equivalent cooling demand. Compared to conventional PID control, the RL strategy mitigated overall thermal loads, reducing motor and controller temperatures by 2°C–5°C and reducer gear temperatures by 1°C–4°C. The equivalent energy-index analysis indicates that the RL strategy suppresses peak temperatures by actively allocating cooling effort during high-load operation, thereby providing a broader thermal safety margin for integrated EDS.