Answers are grounded in this paper and cite their sources.
The shear behaviour of concrete deep beams reinforced with glass-fibre-reinforced polymer (GFRP) with and without vertical web reinforcement was investigated experimentally and analytically. Twelve simply supported specimens were tested under monotonic loading. The main test parameters included the shear span-to-depth ratio (a/d), the GFRP longitudinal reinforcement ratio, the GFRP stirrup spacing and the concrete compressive strength. The test results showed that all the investigated parameters significantly influenced the crack patterns, failure modes, ultimate shear capacity, ductility and energy absorption of the deep beams. Beams with lower a/d exhibited pronounced strut-and-tie action, whereas the addition of GFRP stirrups significantly improved the ductility, monotonic energy absorption capacity and crack control. Finite-element simulations using VecTor2 captured the overall load–deflection behaviour and failure patterns with acceptable accuracy. The predictive capabilities of existing strut-and-tie models (STMs) in various international codes were evaluated. A modified STM was developed by introducing a new strut efficiency factor (βs) that accounts for the effects of selected parameters. Validation against a comprehensive database of 128 deep beams reinforced with FRP bars demonstrated a mean experimental-to-predicted strength ratio of 1.05 with a coefficient of variation of 0.36, outperforming existing design provisions in terms of both accuracy and consistency.
No takes yet. Share an insight, caveat, or question.
Pham et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: