Answers are grounded in this paper and cite their sources.
How well can a passive optical sensor distinguish a weak signal from parasitic coupling when the unwanted interactions follow a known graph? Iseulxûn (CNISA II) answers this question for a coupled-mode model in which the signal directly connects two endpoint modes and defects act along the edges of a calibrated graph. If the endpoints are distance \(d\) apart and \(a\) bounds the integrated operator norm of the defect, the zero-signal endpoint amplitude is at most \(a^d/d!\). A balanced, phase-referenced analyzer retains a linear signed response to the signal. For \(d ≥ 2\), the defect changes its slope by at most \(2La^2\), where \(L\) is the propagation length. The matching converse is constructive. For fixed \(d\) and small \(a\), a sequence of reciprocal edge rotations with controllable signs and phases exactly reproduces the full terminal unitary of a clean signal with rotation angle of order \(a^d\). The two realizations therefore give identical results for every terminal measurement, including tomography with ancillary systems. For \(d ≥ 2\), the local minimax coupling separation at fixed testing error scales as \((a^d + n-1/2)/L\) in the small-defect, large-photon-number regime, using exactly \(n\) photons in the specified input and full collection. When individual edge budgets scale with different powers of a small parameter, the ambiguity exponent becomes a weighted shortest-path distance. A weak parasitic direct link can therefore determine the resolution floor. The manuscript also derives a finite-photon Fisher information bound for a fixed, signal-independent distribution of a defect waveform shared within each shot, with known uniform efficiency \(τ\). In a five-mode chain with \(d=4\), \(a=0.20\), and \(nτ=10^6\), the bound guarantees at least 90.55% of the clean analyzer’s information at the same photon budget and efficiency. Further results include exact carrier compression for one-sided mode ladders, a finite algebraic test for the first defect order visible in a normalized output, an exact finite-length Gaussian return-variance calculation, a nonuniform rectangle sewing theorem, and the closed pole spectrum of a finite root-of-unity ladder. The record pairs the manuscript with editable LaTeX sources, Python verification code, an exact-rational certificate, recorded numerical results, and a figure-generation script. The 13 verification groups include pulse synthesis at distances one through six, with a maximum reported full-matrix residual of approximately \(1.81 × 10⁻¹⁵\). The numerical evidence comes from mathematical models. The manuscript specifies a hardware test that compares a programmed direct signal with its multi-edge imitation using terminal tomography and independently calibrated defect budgets.
No takes yet. Share an insight, caveat, or question.
Nowicki et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: