Electrochemical impedance spectroscopy (EIS) enables noninvasive battery-health assessment, but strong electromagnetic interference (EMI) degrades weak-signal current tracking. This study integrates a fixed-bandwidth linear extended state observer for disturbance estimation, projection-bounded adaptive-gain sliding-mode control with resonant compensation for sinusoidal tracking, and a switchable linear-phase equiripple finite-impulse-response filter bank with group-delay correction. The adaptive law updates the sliding-mode reaching gain, while a composite Lyapunov analysis establishes uniform ultimate boundedness. Experiments on battery cells and a 144 V pack over 0.1 Hz–10 kHz yield 1.2%–1.5% impedance error relative to a Zahner reference and 68.4%–83.7% accuracy improvements over proportional-integral-resonant control.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.