Answers are grounded in this paper and cite their sources.
Boiling crisis limits high-flux heat removal, but conventional hydrodynamic models poorly capture critical heat flux (CHF) on structured surfaces. Here, we report how additively manufactured three-dimensional microporous grids modify bubble evolution and boiling performance. In situ endoscopic imaging reveals two spatially separated three-phase contact lines that develop concurrently along the grid base and upper surface. Across six architectures, the characteristic contact-line expansion rate measured during isolated-bubble growth correlates approximately linearly with CHF. Interconnected pathways may promote liquid redistribution and sustain local liquid-film evaporation, although these processes are not directly quantified. The optimized dual-layer grid reaches a CHF of approximately 331 W/cm 2 , an enhancement of 176% over smooth copper. These findings establish layered contact-line dynamics as an experimentally accessible descriptor associated with boiling stability and suggest a complementary perspective to conventional hydrodynamic descriptions.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: