Answers are grounded in this paper and cite their sources.
Single-particle cryogenic electron microscopy of transducer-free G protein-coupled receptors (GPCRs) relies on fiducial markers to bypass size limits and mitigate micelle-induced low signal-to-noise ratios. However, continuous inter-domain flexibility between the receptor and the marker can limit local resolution. Using modern cryoSPARC algorithms, I reprocessed a previously published dataset of unliganded human Frizzled5 (hFzd5) complexed with a tripartite fiducial system to overcome previous resolution limits. While recent software advancements primarily drove a substantial enhancement in overall resolution, doming-induced specimen tilting and potential domain flexing during electron exposure can still introduce residual blur under a global mask. To resolve this, I restricted trajectory estimation exclusively to the receptor core via focused reference-based motion correction (fRBMC), which provided a further modest improvement in map quality. Subsequent quantitative trajectory analysis showed that the trajectory estimated using a local receptor mask differed from that of the global mask, reaching an average of approximately 2 Å by frame 20. Concluding the workflow with local refinement yielded a final map at 3.27 Å nominal resolution, enabling a more accurate structural re-analysis and interpretation of the extracellular disulfide network.
No takes yet. Share an insight, caveat, or question.
Naotaka Tsutsumi (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: