Key result
Self-expanding Evolut lowers 30-day mean gradients by ~8 mmHg vs SAPIEN in ViV-TAVR.
Why the study?
Previous data comparing balloon-expandable and self-expanding valve systems for valve-in-valve transcatheter aortic valve replacement were limited to retrospective studies.
Does a self-expanding Evolut valve improve 30-day valve hemodynamics compared to a balloon-expandable SAPIEN valve in patients undergoing ViV-TAVR for a failed small (≤23 mm) surgical aortic bioprosthesis?
RCT (n=102)
Randomized
Does a self-expanding Evolut valve improve 30-day valve hemodynamics compared to a balloon-expandable SAPIEN valve in patients undergoing ViV-TAVR for a failed small (≤23 mm) surgical aortic bioprosthesis?
In patients with failed small (≤23 mm) surgical aortic bioprostheses, ViV-TAVR with a self-expanding Evolut valve achieved superior 30-day echocardiographic transvalvular gradients compared to a balloon-expandable SAPIEN valve, though intra-procedural invasive hemodynamics and 30-day clinical outcomes did not differ.
Answers are grounded in this paper and cite their sources.
May inform valve selection in small-annulus ViV-TAVR; leaves open randomized confirmation of either system.
BACKGROUND Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field has been obtained from retrospective studies. OBJECTIVES To compare the hemodynamic results between the balloon-expandable SAPIEN (3/ULTRA) (BEV) and self-expanding Evolut (R/PRO/PRO+) (SEV) valves in ViV-TAVR. METHODS Patients with a failed small (≤23 mm) surgical valve. were randomized to receive a BEV or a SEV. The primary endpoint was valve hemodynamics (maximal/mean residual gradients; severe prosthesis patient mismatch [PPM] or moderate-severe aortic regurgitation [AR]) at 30 days as evaluated by Doppler-echocardiography. RESULTS A total of 102 patients were randomized, and of these, 98 patients finally underwent a ViV-TAVR procedure (BEV: 46, SEV: 52). The procedure was successful in all cases, with no differences in clinical outcomes at 30 days between groups (no death or stroke events). Patients in the SEV group exhibited lower mean and maximal transvalvular gradient values (15±8 vs 23±8 mmHg, p˂0.001; 28±16 vs 40±13 mmHg, p ˂0.001), and a tendency towards a lower rate of severe PPM (44% vs. 64%, p=0.07). There were no cases of moderate-severe AR. 55 consecutive patients (SEV: 27, BEV: 28) underwent invasive valve hemodynamic evaluation during the procedure, with no differences in mean and peak transvalvular gradients between both groups (p=0.41 and p=0.70, respectively). CONCLUSIONS In patients with small failed aortic bioprostheses, ViV-TAVR with a SEV was associated with improved valve hemodynamics as evaluated by echocardiography. There were no differences between groups in intra-procedural invasive valve hemodynamics and 30-day clinical outcomes (NCT03520101).
No takes yet. Share an insight, caveat, or question.
Rodés‐Cabau et al. (2022) conducted an RCT in Failed small (≤23 mm) surgical aortic valve bioprostheses (n=102). Self-expanding Evolut (R/PRO/PRO+) valve (SEV) in ViV-TAVR vs. Balloon-expandable SAPIEN (3/ULTRA) valve (BEV) in ViV-TAVR was evaluated on Valve hemodynamics (maximal/mean residual gradients; severe prosthesis-patient mismatch [PPM] or moderate-severe aortic regurgitation [AR]) at 30 days by Doppler-echocardiography (p=<0.001). Self-expanding Evolut valves in ViV-TAVR lowered 30-day echocardiographic mean and maximal gradients vs balloon-expandable SAPIEN valves.