Answers are grounded in this paper and cite their sources.
A laboratory-scale electromagnetic device was developed for saline water treatment, comprising a control unit (function generator) and a treatment unit: a polyvinyl chloride (PVC) pipe wrapped with a 20 AWG copper coil. This study investigates the effects of electromagnetic field (EMF) exposure on the chemical properties of saline drainage water by monitoring changes in pH and electrical conductivity (EC) (initial values: pH = 7.76 ± 0.01; EC = 5522 ± 9 μS/cm). The examined operating parameters included square-wave frequency (1–4 kHz) and treatment duration (0–30 min) under controlled flow conditions (flow velocity = 1.4 m/s), with a maximum time-varying magnetic field intensity of 13.95 G. The results revealed a nonlinear response of both parameters to electromagnetic field exposure. The pH increased with treatment time and stabilized after about 15 minutes, reaching a maximum value of 8.1 at 3 kHz. In contrast, EC decreased with increasing treatment duration and similarly stabilized after about 15 min, with a minimum value of 5369 µS/cm observed at 3 kHz. These findings suggest that among the tested conditions, electromagnetic field treatment at 3 kHz yields the most pronounced effect on the measured water quality parameters.
No takes yet. Share an insight, caveat, or question.
Jawad et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: