Answers are grounded in this paper and cite their sources.
Purpose This study aims to investigate a unified parametric design framework for laser powder bed fusion (LPBF)-fabricated Ti-6Al-4V scaffolds and compares two architectural classes: a regular rhombic dodecahedron lattice and a stochastic Voronoi-based lattice, with emphasis on macrostructure and mechanical performance. Design/methodology/approach Scaffold geometries were parametrically defined within geometric and manufacturability constraints using open-source mathematical formulations. Specimens were manufactured by LPBF and characterized via gravimetric analysis, X-ray micro-computed tomography (micro-CT) and quasi-static compression testing. Findings Measured structural porosity ranged from ∼59 % to ∼80 %. For rhombic dodecahedron lattices, porosity decreased relative to STL models as unit-cell size decreased, with deviations of 7%–15 %. Voronoi scaffolds showed smaller deviations (−1.5% to 4%). Mechanical properties were strongly correlated with measured porosity. Rhombic dodecahedron structures exhibited Young’s modulus of 1.3–3.7 GPa and apparent yield strength of 41–154 MPa, exceeding those of Voronoi structures (0.9–2.6 GPa and 19–99 MPa, respectively). At fixed geometric parameters, mechanical properties varied approximately linearly with porosity. The governing structural factors differed by topology, with strut number dominating in regular lattices and strut thickness and organic factor governing in stochastic lattices. The results are limited to the investigated geometries and LPBF processing conditions. Fatigue, permeability, biological response and full-scale implant validation were outside the scope of this study. Originality/value The proposed framework enables a direct comparison of regular and stochastic Ti-6Al-4V scaffold architectures fabricated by LPBF and explicitly quantifies discrepancies between nominal CAD designs and as-built structures. By linking topology to manufacturability, porosity deviation and mechanical performance, the study identifies topology-dependent governing parameters: unit-cell size and strut thickness for regular lattices and strut thickness combined with organic factor for stochastic lattices. These results provide design guidelines that incorporate fabrication realities into the optimization of load-bearing orthopedic implants.
No takes yet. Share an insight, caveat, or question.
Tvorogov et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: