Answers are grounded in this paper and cite their sources.
The challenges associated with processing highly viscous reactive mixtures in microfluidic systems were investigated using the synthesis of an industrially relevant polyurethane prepolymer from PTMEG‐2000 and H12‐MDI as a model reaction. Continuous experiments conducted in a quartz microfluidic reactor chip with passive serpentine mixing geometry exhibited substantial deviations in both viscosity evolution and kinetic behavior relative to well‐mixed batch operations. Visibly separate layers in the effluent comprised different NCO compositions, indicating inadequate homogenization within the microfluidic system, consistent with low Reynolds and Dean numbers. Although mixing of the effluent, before further reaction, restored kinetic behavior comparable to batch experiments, viscosity differences persisted, suggesting structural differences in the resulting polymer products. Gel permeation chromatography (GPC) analysis supported this hypothesis by revealing that higher viscosities did not correlate with elevated molecular weights. These results demonstrate that passive microfluidic mixing strategies commonly employed for low‐viscosity systems may be inadequate for highly viscous polymerizing systems.