Key result
3D image fusion during TEVAR achieves 100% target intercostal artery patency with no spinal ischemia.
Why the study?
Preserving intercostal arteries during thoracic aortic procedures reduces post-operative paraparesis risk, yet their origins are visible on pre-operative CTA and rarely seen on intra-operative angiography.
Does 3D image fusion of pre-operative CTA and intra-operative CBCT enable localisation and preservation of intercostal arteries during TEVAR?
Observational (n=7)
No
Does 3D image fusion of pre-operative CTA and intra-operative CBCT enable localisation and preservation of intercostal arteries during TEVAR?
3D image fusion of pre-operative CTA and intra-operative cone-beam CT is a feasible technique to localise and preserve intercostal arteries during TEVAR, potentially reducing the risk of spinal cord ischaemia.
Answers are grounded in this paper and cite their sources.
3D fusion feasible for intercostal preservation in TEVAR; hypothesis-generating, requires prospective trials before adoption.
PURPOSE: Preservation of intercostal arteries during thoracic aortic procedures reduces the risk of post-operative paraparesis. The origins of the intercostal arteries are visible on pre-operative computed tomography angiography (CTA), but rarely on intra-operative angiography. The purpose of this report is to suggest an image fusion technique for intra-operative localisation of the intercostal arteries during thoracic endovascular repair (TEVAR). TECHNIQUE: The ostia of the intercostal arteries are identified and manually marked with rings on the pre-operative CTA. The optimal distal landing site in the descending aorta is determined and marked, allowing enough length for an adequate seal and attachment without covering more intercostal arteries than necessary. After 3D/3D fusion of the pre-operative CTA with an intra-operative cone-beam CT (CBCT), the markings are overlaid on the live fluoroscopy screen for guidance. The accuracy of the overlay is confirmed with digital subtraction angiography (DSA) and the overlay is adjusted when needed. Stent graft deployment is guided by the markings. The initial experience of this technique in seven patients is presented. RESULTS: 3D image fusion was feasible in all cases. Follow-up CTA after 1 month revealed that all intercostal arteries planned for preservation, were patent. None of the patients developed signs of spinal cord ischaemia. CONCLUSION: 3D image fusion can be used to localise the intercostal arteries during TEVAR. This may preserve some intercostal arteries and reduce the risk of post-operative spinal cord ischaemia.
No takes yet. Share an insight, caveat, or question.
Koutouzi et al. (2017) conducted an observational in Thoracic aortic aneurysm or chronic expanding aortic dissection requiring TEVAR (n=7). 3D/3D image fusion of pre-operative CTA with intra-operative cone-beam CT for intercostal artery localisation during TEVAR was evaluated on Feasibility of 3D image fusion and 1-month patency of intercostal arteries planned for preservation. 3D image fusion during TEVAR was feasible in 100% of 7 patients, resulting in 100% patency of all 15 intercostal arteries planned for preservation at 1 month and 0% spinal cord ischaemia.