Key result
Hostile proximal neck anatomy was not associated with higher overall 2-year reintervention after standard EVAR compared to standard anatomy.
Why the study?
The short-term safety, 2-year durability, and anatomical predictors of reintervention after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) with hostile proximal neck anatomy required evaluation.
Does hostile proximal neck anatomy increase the risk of 2-year reintervention and 30-day adverse events compared to standard proximal neck anatomy in patients undergoing elective standard endovascular aneurysm repair for infrarenal abdominal aortic aneurysms?
Cohort (n=398)
No
Does hostile proximal neck anatomy increase the risk of 2-year reintervention and 30-day adverse events compared to standard proximal neck anatomy in patients undergoing elective standard endovascular aneurysm repair for infrarenal abdominal aortic aneurysms?
In patients undergoing elective standard EVAR for infrarenal AAA, hostile proximal neck anatomy overall had comparable 30-day safety and a non-significant increase in 2-year reintervention compared to standard anatomy, though having ≥2 hostile neck features or tapered/reverse-tapered neck morphology significantly increased 2-year reintervention risk.
Answers are grounded in this paper and cite their sources.
Does not support restricting standard EVAR for hostile proximal necks; leaves open whether multiple features or tapered morphology increase reintervention risk.
Objective To evaluate the short-term safety and 2-year durability of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) with hostile proximal neck anatomy and to identify anatomical predictors of reintervention. Methods We screened 637 EVAR patients treated at Nanjing Drum Tower Hospital from January 2019 to December 2021. After exclusions, 398 patients with infrarenal AAAs treated with elective standard EVAR were included and classified into the standard anatomy group (SAG, n = 266) or hostile proximal neck group (HPG, n = 132). Cox regression was used as the primary analysis for 2-year reintervention, with logistic regression as sensitivity analysis. Results Technical success was achieved in all patients. The HPG was older and had more complex aneurysm morphology. Thirty-day serious adverse events were comparable between the SAG and HPG (3.0% vs. 2.3%; P = 1.000). During 2-year follow-up, reintervention occurred in 45 SAG patients and 32 HPG patients (16.9% vs. 24.2%; 2-year freedom from reintervention, 83.1% vs. 75.8%; log-rank P = .078). The unadjusted hazard ratio for reintervention in the HPG versus the SAG was 1.50 (95% CI, 0.95–2.36, P = .081). The clinically adjusted estimate was similar in a stratified sensitivity model with time-varying age effects (HR, 1.60; 95% CI, 0.98–2.61). Within the HPG, patients with ≥2 hostile features had lower 2-year freedom from reintervention than those with a single feature (70.6% vs. 85.1%; log-rank P = .041), and the pooled tapered/reverse-tapered neck category was associated with reintervention in an exploratory analysis (HR, 3.70; 95% CI, 1.83–7.45; P < .001). Conclusion In this selected cohort, 30-day adverse event rates were similar between anatomical groups. Greater hostile anatomical feature burden and tapered/reverse-tapered neck morphology were associated with higher 2-year reintervention risk, whereas the overall HPG-versus-SAG association did not reach statistical significance. These exploratory findings warrant validation in larger cohorts.
No takes yet. Share an insight, caveat, or question.
Zhigao et al. (2026) conducted a cohort in Infrarenal abdominal aortic aneurysm undergoing elective standard endovascular aneurysm repair (EVAR) (n=398). Hostile proximal neck anatomy (short neck <15 mm, angulation >60°, calcification/thrombus >50% circumference, or tapered/reverse-tapered neck) vs. Standard proximal neck anatomy was evaluated on 2-year reintervention (HR 1.50, 95% CI 0.95-2.36, p=0.081). Hostile proximal neck anatomy was not associated with higher overall 2-year reintervention after standard EVAR compared to standard anatomy.
Synapse has enriched 10 related papers. Consider them for comparative context: