Answers are grounded in this paper and cite their sources.
The circulating water pump unit is essential equipment in a nuclear power plant, responsible for cooling the discharged steam from the turbine. Its structural rigidity is relatively low, making it prone to driving motor or spline-coupled gearbox input shaft faults. To address the challenges, we focus on improving health state classification accuracy through designing a new technical routine, which integrates vibration signals from condition monitoring with infrared thermal images from on-site inspections. We develop an application-oriented multi-scale, multi-dimensional feature-fusion framework to enhance the diagnostic accuracy of varying dimensions across multiple scales. This is achieved by fusing, concatenating, and classifying features from different data sources at the same scale. Feature fusion across different dimensions relies on concatenation, segmentation, and re-concatenation operations within an attention-based fusion module. Effectiveness of our work is validated using both experimental and on-site datasets, supporting its effectiveness in the evaluated health state classification tasks given limited faulty-state training data.
No takes yet. Share an insight, caveat, or question.
Cui et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: