Answers are grounded in this paper and cite their sources.
Background/Objectives: Mandibular fractures frequently require restoration of occlusion, stabilization of bone fragments, and maintenance of intermaxillary relationships during healing. Conventional Erich arch bars remain a widely used method of maxillomandibular fixation (MMF) but are associated with prolonged operative time, mucosal trauma, plaque accumulation, needle-stick risk, and reduced comfort. Bone-supported intermaxillary fixation (IMF) screws have been introduced as an alternative, yet screw-related complications continue to limit their universal adoption. This narrative review synthesizes the clinical, morphological, biomechanical, technical, and practical rationale for a proposed method of mandibular fracture stabilization using self-tapping titanium orthodontic screws, with heads placed intraorally in the alveolar process of the maxilla and mandible, connected by elastic intermaxillary traction. Methods: A narrative literature review was undertaken across five thematic domains: mandibular fracture management, Erich arch bars, intermaxillary fixation screws, orthodontic miniscrews, and the biomechanics of elastic maxillomandibular fixation. The search was iterative and performed by a single reviewer; no record counts or formal eligibility criteria were recorded, and the evidence tables rely on abstracts and, where available, full texts. The proposed technique was appraised against existing fixation concepts and their documented limitations. Results: Screw-based intermaxillary fixation can shorten operative time and avoid extensive circumdental wiring relative to conventional arch bars, with a potential but meta-analytically mixed hygiene benefit. Elastic traction between screws is not new: it was described as “Elastic Internal Traction” in 2004, IMF screws with orthodontic elastic chains were reported in 2024, and a small clinical series used orthodontic mini-implants for intermaxillary fixation of mandibular fractures in 2017. The present proposal differs mainly in its explicit, provisional placement scheme (approximately 8 mm from the gingival margin, at least one tooth from the fracture edge), which is an experimental design parameter that has not been anatomically validated, and in its symmetrical elastic configuration; its biomechanics have not been tested. Conclusions: Orthodontic screw-assisted intermaxillary fixation is a hypothesis-generating intraoral concept for selected mandibular fractures, with potential advantages of reduced intraoral bulk and easier hygiene access relative to arch bars, extrapolated from conventional IMF screws and hybrid arch bars. Whether it provides adequate fragment stabilization is unknown. Anatomical CBCT and cadaveric studies, biomechanical testing, and prospective clinical studies would be required before any clinical use could be considered.
No takes yet. Share an insight, caveat, or question.
Boymurodov et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: