Answers are grounded in this paper and cite their sources.
Flexible piezoionic strain sensors are promising in wearable electronics and health monitoring. However, material interface fatigue and delamination caused by repeated strain seriously affect the stability and service life of piezoionic sensors. Conventional adhesive materials can not completely repair device structure and performance. Here, we propose a thermal-healing gelatin interface based on the sol-gel transition effect that effectively repairs interface micro-gaps and ion transport pathway. The as-prepared piezoionic sensor with interface damage is repaired just upon heating, and the sensing performance recovers by more than 97% of the pristine one. The restoration efficiency of our strategy outperforms previously reported healing methods for strain sensors. The flexible sensor is employed as wearable and healable switch for underwater operation. The study provides a versatile way for performance repair of electrochemical devices.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: