To address the issue of coarse and fine coal particles entering the underflow during the sorting process in hydrocyclones, resulting in low recovery rates of fine coal in the overflow, this paper proposes an aerated hydrocyclone. To evaluate the separation performance of the proposed hydrocyclone, a series of separation experiments were carried out under different operating and structural conditions, which investigated the influence of aeration flow rate, equivalent diameter of the aeration port, cone angle, and underflow outlet diameter on the separation performance of the aerated water-medium hydrocyclone. The results indicate that appropriately increasing the aeration flow rate can improve the recovery rate of coarse clean coal, while the size of the air inlet has little effect on this recovery rate. Excessively large cone angles and underflow outlet diameters are detrimental to coal recovery. A predictive model for sorting performance indicators was established, and an optimal parameter combination was identified. When the aeration flow rate is 15 L/min, the underflow outlet diameter is 20 mm, the cone angle is 120°, and the equivalent diameter of the air inlet is 4.8 mm, the ash content of the coarse clean coal is less than 10%, and the recovery rate reaches 37.36%.