This study investigates square-wave excitation in a fundamental-mode orthogonal fluxgate (FM-OFG) sensor. A numerical model combining Stoner–Wohlfarth theory and Fourier analysis predicts equal-amplitude odd-order voltage harmonics under ideal instantaneous-switching conditions. A U-shaped sensor was fabricated using a CoFeSiBCrMo amorphous wire core and two 400-turn pick-up coils connected in opposition. We varied the excitation frequency and current amplitude and selected operating settings of 124 kHz, 37 mA DC bias, and 35 mA AC peak current. Under equal peak AC current amplitude, square-wave excitation achieves a sensitivity of 9.55 × 104 V/T and an equivalent magnetic field noise of 7.62 pT/Hz @1 Hz, corresponding to a 31.54% sensitivity increase and a 29.90% noise reduction relative to sinusoidal excitation. Under equal fundamental-component current amplitude, sensitivity increases by 4.13% and equivalent magnetic field noise decreases by 12.42%. Under equal RMS current, sensitivity decreases by 7.58%, while equivalent magnetic field noise decreases by 2.12%. These results demonstrate that square-wave excitation can reduce the sensor’s equivalent magnetic field noise under the tested conditions.