Bioactive resin composites are increasingly used, yet data on their mechanical properties, particularly at the nanoscale, remain limited. This study compared two bioactive (Stela Automix, SA; Activa Presto, AP) and two conventional (Tetric N-Ceram 2, TN; Filtek Supreme Flowable, FS) resin composites using Vickers micro-hardness and nanoindentation. Disc-shaped specimens (8 × 2 mm; n = 15/group) were prepared; TN, AP, and FS were light-cured for 20 s per side with a polywave LED curing unit (1200 mW/cm2), whereas SA was self-cured for 4 min. After polishing and one-week storage at 37 °C, Vickers micro-hardness, nano-hardness, and elastic modulus were measured on the same surface. Data were analyzed using Kruskal–Wallis, Welch ANOVA, and Spearman correlation tests. All parameters differed significantly among materials (p < 0.001), with TN and SA generally ranking highest. AP showed the lowest values overall (elastic modulus: 7.51 ± 0.36 GPa; p < 0.001 vs. all other materials) and was the only material without a significant correlation between nano-hardness and Vickers hardness (r = 0.314, p = 0.254). Elastic modulus correlated strongly with hardness in the pooled data (r = 0.772–0.806) but not within individual materials. Within the tested materials, the “bioactive” designation was not associated with a uniform mechanical profile, and the two methods showed weaker agreement for AP than for the other materials.