Answers are grounded in this paper and cite their sources.
To achieve staged energy dissipation under multi-level earthquakes, a Contact-Triggered Dual-Stage Shear Panel Damper (CTDSPD) is proposed. A reserved gap between the primary and secondary dampers controls the activation of the secondary dampers, enabling a transition from energy dissipation by the primary damper to coupled energy dissipation by the primary and secondary dampers. A finite-element modeling approach was first verified against existing tests on conventional shear panel dampers and was then used to investigate 13 CTDSPD parametric specimens considering the activation gap, height-to-width ratio, and thickness of the secondary core plate. A simplified multilinear restoring-force model was also developed. Under the investigated cyclic loading protocol, the FE results show generally full hysteresis loops without obvious pinching, limited strength degradation, and a distinct dual-stage energy-dissipation response. The activation gap mainly governs the activation timing and plastic development of the secondary dampers, while the height-to-width ratio affects deformation compatibility and local stress concentration. Increasing the secondary core-plate thickness improves load-carrying capacity and cumulative energy dissipation but reduces energy-dissipation density and may aggravate local instability. The proposed restoring-force model reasonably represents the stage transition and strength development, with average errors of 5.31%, 5.34%, and 5.33% at loading displacements of 14.1, 23.5, and 37.6 mm, respectively.