Answers are grounded in this paper and cite their sources.
Voltage-source inverters supply the permanent magnet synchronous motors (PMSMs) of electric vehicles and industrial drives, and their switches often fail. This paper evaluates machine learning and deep learning models for nine operating conditions of an inverter-driven PMSM (normal operation and two open-circuit, three short-circuit and three overheating faults), using a public 24-channel dataset sampled at 10 Hz. Each class was recorded as one contiguous block, so random splits place near-copies of test windows in the training set. A blocked 5-fold cross-validation with a guard band equal to the window length was used, and all model choices were made on chronological inner validation splits. Eighteen analytical classifiers and nineteen deep architectures with two ensembles were trained on features from five signal transforms and explained with LIME and SHAP. CatBoost reached 98.99 ± 2.01% accuracy and an ensemble of five Transformers 98.78 ± 2.13%. With a fixed, preliminary feature set, a random split raised the mean accuracy of the analytical models from 94.95% to 99.49%. The raw logs show that every class is a separate recording. The temperature channels alone gave up to 99.2% accuracy and the electrical channels alone at most 77.3%, and a 1 °C thermistor offset lowered CatBoost to 47.4%. The results therefore describe discrimination within these recordings, not transfer to new sessions.
No takes yet. Share an insight, caveat, or question.
Ertasgin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: