Answers are grounded in this paper and cite their sources.
This study reports doping of boron into graphitic carbon nitride (B-GCN) to improve conductivity and induce active sites for sensing of carbofuran, a toxic and hazardous pesticide found in surface water. Doping boron into GCN by the condensation method and modified B-GCN was used for modification of glassy carbon electrode (GCE) by drop-casting. The conductivity of the B-GCN modified electrode was increased 11-fold compared to bare GC electrodes as assessed by the ferrocene/ferrocenium redox couple in 0.1 M KCl. Fabricated B-GCN/GCE was used to determine carbofuran via differential pulse voltammetry (DPV) mode using phosphate buffer of pH 7 as electrolyte of the choice. The sensor demonstrated a linear relationship over a wide concentration range of 0.33 – 2.02 µM with (R2 value of 0.99). The lower detection limit (LOD) of the sensor was found to be 0.27 µM while the limit of quantification was 0.83 µM. The sensor was used to detect carbofuran in real water samples after cleaning and preconcentration using solid phase extraction technique which enabled the sensor to detect carbofuran down to 0.118 µM well below the allowable limit of 7 µg/L by WHO.
No takes yet. Share an insight, caveat, or question.
Pirzada et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: